Review No:2 , ALUS DESCRIPTION := BUILDING PLAN CHECK
Employee ID =WSEIFERT Reviewer information : Employee Name = WALT SEIFERT
Employee ID =WSEIFERT
1. Provide dimensions of space to be converted so that exiting may be determined 2. Coordinate the header dimensions. The 6'-10" dimension is at two different locations of the header ofthe views shown. 3. Specify 1-1/2 inches clearance between the handrail grip and the wall. OCTOBER 14, 1997. DEAR APPLICANT: FOR THE HANDRAILS,PROVIDE NOT LESS THAN 12 INCH EXTENSIONS BEYOUND TOP AND BOTTOM RISERS. ENDS SHALL SHALL BERETURNED OR SHALL TERM- INATE IN NEWEL POST OR SAFETY TERMINALS.1994 UBC SECTION 1006.9a. FOR THE HANDRAILS, ALL SHARP CORNERS, ON GRIPABLE PORTION, SHALL HAVE A MINIMUM RADIUS OF NOT LESS THAN 1/8-INCH.Section 1006.9a. IN ADDITION TO THE PROVISIONS OF CHAPTER 10, EXITS WHICH PROVIDE ACCESS TO, OR EGRESS FROM, BUILDINGS FOR PERSONS WITH DISABILITIES SHALL ALSO COMPLY TO CHAPTER 11, 1994 UBC. PLEASE SPECIFY MERCHANDISE TO BE STORED IN STORAGE. FOR EXAMPLE, GALLONS OF PAINT, PAINT THINNER, AND OTHER CLEANING SOLVENTS. OBSTRUCTIONS SHALL NOT BE PLACED IN THE REQUIRED WIDTH OF AN EXIT EXCEPT PROJECTIONS AS PERMITTED BY CHAPTER 10, 1994 UBC. UBC FOR EXAMPLE, A DOOR THAT IS LOCATED IN THE STORAGE ROOM CANNOT SERVE AS AN EXIT, UNLESS THAT EXIT IS PROVIDED WITH AN APPROVED FIRE RATED CORRIDOR.1994 UBC SECTION 1001.3. SINCE TWO EXITS ARE REQUIRED PER UBC TABLE 10-A, THEY SHALL BE PLACED A DISTANCE APART EQUAL TO NOT LESS THAN ONE HALF OF THE OF THE LENGTH OF THE OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED IN A STRAIGHT LINE BERTWEEN EXITS. THE SECOND EXISTING FRONT DOOR ADJACENT TO THE AREA OF CONSIDERATION DOES NOT MEET THESE REQUIREMENTS AND CANNOT BE CONSIDERED A SECOND REQUIRED EXIT.1994 UBC SECTION 1003.4. PLEASE PROVIDE SPECIES AND GRADE OF LUMBER FOR HEADER AND STAIR CONSTRUCTION. THE USE OF PLYWOOD AS STRINGERS IS NOT ACCEPTABLE FOR POSITIVE CONNECTION (PLYWOOD PROVIDES NIL END NAILING CAPACITY). PLEASE PROVIDE SPECIFICATIONSN FOR 2X STRINGERS AND SPECIFY THE CONNECTION METHOD, SUCH AS PREDRILLED HOLES INTO TREADS INTO STRINGERS WITH ACCEPTABLE SCREWS. PLEASE SPECIFY THE METHOD FOR CONNECTING THE BALUSTERS TO THE HANDRAILS. PLEASE PROVIDE THESE REQUIREMENTS ON A REVISED SET OF CONSTRUCTION PLANS. SHOULD ACCESSIBILITY COMPLIANCE BE REQUIRED (TO BE DETERMINED BY STAFF PER TITLE 24) PLEASE INCORPORATE INTO THE CONSTRUCTION PLANS.Review No:1 , ALUS DESCRIPTION := BUILDING PLAN CHECK
Employee ID =WSEIFERT Reviewer information : Employee Name = WALT SEIFERT
Employee ID =WSEIFERT Reviewer information : Employee Name = WALT SEIFERT
Employee ID =WSEIFERT
NO PROJECT REVIEW DESCRIPTION AVAILABLE
|