Review No:1 Employee Record is no longer valid + employeeid = JPEREZ, ALUS DESCRIPTION := ACCESSIBILITY
Reviewer information : Employee Name = MICHAEL BUSH
Employee ID =MBUSH
Accessibility Plan Check comments: 1. Provide site plan which shows nearest accessible parking to this tenent space. Demonstrate accessible path of travel to this space. 2. Provide interior wheel chair access from existing space to proposed space. It is not acceptable to go outside. Questions regarding accessibility can be directed to Michael Bush, 454-3236. 2-5-97 Second cash register added at lower floor, so no ramp or lift will be required between floors. A cowardly solution but its none of my business.Review No:3 , ALUS DESCRIPTION := BUILDING PLAN CHECK
Employee ID =RWOOD
Plan check comments: 1. Provide 1/8" scale floor plan for both halves of proposed tenant space. Include all furnishing, aisles, counters, exits, and exit illumination. 2. Provide details for proposed stairs which comply with 1994 UBC section 1006. Provide center handrail and hand rail extensions per appropriate code sections, and provide cross section of handrail to comply with UBC 1006.9. Please prepare two sets of revised plans and/or documents which incorporate these corrections and submit them with a copy of this letter to the Building Counter, Fourth floor, County Administrative Center, 701 Ocean street, Santa Cruz, California 95060. It is not necessary to make an appointment; however, please sign up at the Building Counter so that the plans and/or documents receive the required initial screening and are routed correctly to the appropriate agencies. If you have any questions about these corrections, please call Michael Bush @ 454-3236 between the hours of 1:00-5:00 p.m. sONDAY THRU THURSDAY Second plan check 2-5-97 Provide handrail extensions per UBC 1006.9 for the stair handrails. PLEASE NOTE: 1. Pencil is not allowed on construction documents. Please incorporate the pencil changes you made to the sheet submitted into your drawings before reproduction. 2. Scale cross section of handrail.Review No:2 Employee Record is no longer valid + employeeid = JPEREZ, ALUS DESCRIPTION := BUILDING PLAN CHECK
Employee ID =RWOOD Reviewer information : Employee Name = MICHAEL BUSH
Employee ID =MBUSH
NO PROJECT REVIEW DESCRIPTION AVAILABLE Review No:1 , ALUS DESCRIPTION := BUILDING PLAN CHECK
Employee ID =MBUSH Reviewer information : Employee Name = MICHAEL BUSH
Employee ID =MBUSH