Building Review

Review No:1

1. Please submit energy compliance form NRCC-LTS-01-E for sign lighting. This form shall be signed by the energy compliance author and lighting designer for the sign. [CA Energy Standard 10-103(a)1.

 


2. All outdoor sign lighting is required to be controlled with one of the following two options:


     a. A photocontrol in addition to an automatic time-switch control, or


     b. An astronomical time-switch control.


     [CA Energy Standard 130.3(a)]

 


3. All outdoor sign lighting that is ON both day and night shall be controlled with a dimmer that provides the ability to automatically reduce sign lighting power by a minimum of 65 percent during nighttime hours.


Signs that are illuminated at night and for more than 1 hour during daylight hours shall be considered ON both day and night.


     [CA Energy Standard 130.3(a)]

 


4.  Specify grounding and bonding for the signs and metal parts and equipment per CEC 600.7. 

 


If you have any questions regarding these building plan check comments above, please contact Laura Brinson at 831-454-3151 or email laura.brinson@santacruzcounty.us .