Building Review |
|
1. Reverse the door swing for the café use in building 2, as the occupant load exceeds 50. All doors serving an occupant load of 50 or more shall be equipped with panic hardware (except main exit for A occupancies that have sign described in item 6 below). [CBC 1004, 1008.1.10] 2. Please provide penetration details and specifications for openings in fire-resistive construction to comply with CBC 714. 3. There are 2 water closets required to serve the Café of Building 2, as calculated on A3.4 for the tenant improvement plan set. Please revise the plans. [CPC Table 433.1] 4. Please note on the cover sheet of the plans that a Certificate of Acceptance for lighting controls is required by final inspection. The certificate shall be completed by a Certified Lighting Controls Acceptance Test Technician (CLCATT). A CLCATT may be found @ https://www.calctp.org/ . [CA Energy Standard 130.4] 5. Please indicate the type of light fixtures and controls on Sheet A4 to correspond with the requirements in the CA Energy Standards and the energy compliance documents.
Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. Have changes made to the plans not resulting from this correction list? Please check ____________Yes ______________No If Yes, please describe the changes and where they are located in the plans:
Note: For the referenced code information, go to http://www.bsc.ca.gov/Codes.aspx and/or http://www.sccoplanning.com/PlanningHome/BuildingSafety/BuildingCodes.aspx . Please be advised that if plan check comments are required to be addressed leading to a 3rd plan check, additional charges will be added to your permit fee at an hourly rate. If you have any questions regarding these building plan check comments above, please contact Laura Brinson at 831-454-3151 or email laura.brinson@santacruzcounty.us . |